HILTI HST ANCHOR PDF

Items 1 – 10 of 22 Download free 3D files & 2D drawings – Mechanical anchor – Type HST. Ultimate-performance expansion anchor for cracked concrete. 2 Content. Anchor Types for temporary fastening of Diamond Equipment. ▫ HKD drop-in anchors. ▫ HST stud anchors. ▫ HUS3 screw anchor.

Author: Zulkir Taujind
Country: Argentina
Language: English (Spanish)
Genre: Science
Published (Last): 19 August 2010
Pages: 248
PDF File Size: 13.8 Mb
ePub File Size: 10.25 Mb
ISBN: 576-5-30710-804-3
Downloads: 19568
Price: Free* [*Free Regsitration Required]
Uploader: Akikus

Engineering Support on Call Hilti engineers are available to assist you in your design and project submission for approvals, at no additional cost.

Acnhor system includes injection adhesive in More information. Push-in anchor, Anchor version Carbon steel with lip -S R Carbon steel, stainless steel with lip -E R Carbon steel, stainless steel without lip Benefits – simple and well proven – approved, tested and.

To make this website work, we log user data and share it with processors.

Revision of calculation can be carried out by Hilti Profis Anchor software or as per Hilti anchor design manual. Chemical Anchoring – Anchor Studs Anchorage depth hef [mm] Non-cracked concrete Tensile NRd [kn] 8,0 8,5 13,3 11,9 16,7 17,6 anxhor 34,2 40,0 -R [kn] ancho 8,5 13,3 11,9 16,7 17,6 26,4 34,2 40,0 Shear VRd [kn] 11,0 17,5 18,9 27,2 28,3 43,6 44,2 67,1 62,7 -R [kn] 12,6 20,5 20,2 24,9 29,4 38,9 50,9 77,8 88,5 Cracked concrete Tensile NRd [kn] 5,0 6,1 8,0 8,5 13,3 12,6 18,8 24,4 26,7 -R [kn] 5,0 6,1 8,0 8,5 13,3 12,6 18,8 24,4 26,7 Shear VRd [kn] 11,0 16,2 18,9 23,6 28,3 42,9 44,2 67,1 62,7 -R [kn] 12,6 16,2 20,2 23,6 29,4 38,9 50,9 77,8 83,9 Recommended loads Anchor size M8 M10 M12 M16 M20 M24 Eff.

  LEXICON MPX 110 MANUAL PDF

Advantages Highest resistance for geometrically challenging requirements, e. Polyester based injection resin, styrene free. Popular Products from Hilti. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. Anchorage depth hef [mm] Non-cracked concrete Tensile NRu,m [kn] 15,9 17,0 26,6 23,7 33,2 35,1 52,5 68,1 79,7 -R [kn] 15,9 17,0 26,6 23,7 33,2 35,1 52,5 68,1 79,7 Shear VRu,m [kn] 14,5 23,0 24,8 35,7 37,2 57,2 58,1 88,1 98,7 -R [kn] 16,5 26,9 26,6 32,7 38,5 51,0 66,8 ,1 ,8 Cracked concrete Tensile NRu,m [kn] 10,0 12,1 15,9 16,9 26,6 25,0 37,5 48,5 53,1 -R [kn] 10,0 12,1 15,9 16,9 26,6 25,0 37,5 48,5 53,1 Shear VRu,m [kn] 14,5 23,0 24,8 35,7 37,2 57,2 58,1 88,1 98,7 -R het 16,5 26,9 26,6 32,7 38,5 51,0 66,8 ,1 ,8 Characteristic resistence Anchor size M8 M10 M12 M16 M20 M24 Eff.

Aziz 1A. S KA H stainless steel K hot dip galvanized. Combined tension and shear loading For combined tension and shear loading see section Anchor Design.

BIM/CAD Library

The influencing factors must then be considered for each edge distance and spacing. Chemical Anchoring – Anchor Studs 9. The method may also be applied for anchor groups with more than two anchors or more than one edge. The new anchor series is of equivalent or better specifications than current HST anchor. Significantly higher loads can be achieved at the same embedment depth and application on thinner slabs is approved.

These influencing factors must be considered for every edge distance. Designers and engineers asked for it, so Hilti delivered: Higher load performance at the same embedment depth The new presents two embedment depths that make design more versatile.

Please refer to the publication in its entirety for complete details on this product More information. Construction Uses Characteristics More information. Static mixer HIT M1. Best shear resistance with no compromise on ductility with the premium bolt material and cold forming technology. Load performance exhibits higher or equivalent load performance in terms of tension and shear loads, compared to HST.

  BIR RR 2-98 PDF

Products offered by Hilti include powder-actuated fastening, drilling and demolition, diamond coring and cutting, measuring — construction lasers and sensors, firestop — passive fire resistance, screw fastening and adhesive and uilti anchoring. Hangers and supports for electrical equipment and systems.

Dependable Documents and Approvals Hilti anchors are designed and tested under European Technical Approvals ETA for cracked and uncracked concrete, hiltu well as dynamic loading applications e.

10 X Anchor Bolts Hilti Hst M16x140/25 (371593)

The Stud Anchor HST is suitable for applications in cracked concrete and also be used on facades, hand rails, racks and mechanical equipment. For detailed lead time information please contact your Hilti representative.

This Section includes the. Edge and anchor spacing distance requirements requires a smaller or equivalent edge and anchor spacing distances refer to Hilti anchor design manual. You are well supported with comprehensive technical information and test reports for your project approval at Buildings Department, Housing Authority, Architectural Services Department, etc.

Admissible loads in concrete as well as P.

Click here to upgrade your browser. It can be used in a More information.

Start display hsy page:. To use this website, you must agree to our Privacy Policyincluding cookie policy. No concrete splitting may occur when placed close to edge and another anchor.